View Latest Blog Entries
Close
Categories
Testing & Assessment Certification Standard & Regulation Aging Wires & Systems Maintenance & Sustainment Management Conference & Report Protection & Prevention Research Miscellaneous Arcing
Popular Tags
Visual Inspection High Voltage AS50881 MIL-HDBK MIL-HDBK-525 FAR AS4373 Maintenance Electromagnetic Interference (EMI) FAR 25.1707 Wire System Arcing Damage
All Tags in Alphabetical Order
2021 25.1701 25.1703 abrasion AC 33.4-3 AC 43 Accelerated Aging accessibility ADMT Aging Systems AIR6808 AIR7502 Aircraft Power System aircraft safety Aircraft Service Life Extension Program (SLEP) altitude arc damage Arc Damage Modeling Tool Arc Fault (AF) Arc Fault Circuit Breaker (AFCB) Arc Track Resistance Arcing Arcing Damage AS22759 AS22759/87 AS23053 AS29606 AS4373 AS4373 Method 704 AS50881 AS5692 AS6019 AS6324 AS81824 AS83519 AS85049 AS85485 AS85485 Wire Standard ASTM B355 ASTM B470 ASTM D150 ASTM D2671 ASTM D8355 ASTM D876 ASTM F2639 ASTM F2696 ASTM F2799 ASTM F3230 ASTM F3309 ATSRAC Attenuation Automated Wire Testing System (AWTS) Automotive Avionics backshell batteries bend radius Bent Pin Analysis Best of Lectromec Best Practice bonding Cable Cable Bend cable testing Carbon Nanotube (CNT) Certification cfr 25.1717 Chafing Chemical Testing Circuit Breaker circuit design Circuit Protection cleaning clearance Coaxial cable cold bend collision comparative analysis Compliance Component Selection Condition Based Maintenance Conductor Conductor Testing conductors conduit Connector Connector rating connector selection connector testing connectors contacts Corona Corrosion Corrosion Preventing Compound (CPC) corrosion prevention Cracking creepage D-sub data analysis data cables degradat Degradation Delamination Derating design safety development diagnostic Dielectric breakdown dielectric constant Dimensional Life disinfectant Distributed Power System DO-160 dry arc dynamic cut through E-CFR electric aircraft Electrical Aircraft Electrical Component Electrical Power Electrical Testing Electrified Vehicles Electromagnetic Interference (EMI) Electromagnetic Vulnerability (EMV) Electrostatic Discharge EMC EMF EN2235 EN3197 EN3475 EN6059 End of Service Life End of Year Energy Storage engines Environmental Environmental Cycling environmental stress ethernet eVTOL EWIS certification EWIS Component EWIS Design EWIS Failure EWIS sustainment EWIS Thermal Management EZAP FAA FAA AC 25.27 FAA AC 25.981-1C FAA Meeting failure conditions Failure Database Failure Modes and Effects Analysis (FMEA) FAQs FAR FAR 25.1703 FAR 25.1707 FAR 25.1709 Fault fault tree Fixturing Flammability fleet reliability Flex Testing fluid exposure Fluid Immersion Forced Hydrolysis fuel system fuel tank ignition Functional Hazard Assessment functional testing Fundamental Articles Fuse Future Tech galvanic corrosion Glycol Gold Gold plating Green Taxiing Grounding hand sanitizer handbook Harness Design harness protection hazard Hazard Analysis health monitoring heat shrink heat shrink tubing high current high Frequency high speed data cable High Voltage High Voltage Degradation HIRF History Hot Stamping Humidity Variation HV connector HV system ICAs IEC 60851 IEC60172 IEEE immersion insertion loss Inspection installation installation safety Instructions for Continued Airworthiness insulating material insulating tape Insulation insulation breakdown insulation resistance insulation testing interchangeability IPC-D-620 ISO 17025 Certified Lab ISO 9000 J1673 Kapton Laser Marking life limit life limited parts Life prediction life projection Lightning lightning protection liquid nitrogen lithium battery lunar Magnet wire maintainability Maintenance Maintenance costs Mandrel mean free path measurement mechanical stress Mechanical Testing MECSIP MIL-C-38999 MIL-C-85485 MIL-DTL-17 MIL-DTL-23053E MIL-DTL-3885G MIL-DTL-38999 MIL-E-25499 MIL-HDBK MIL-HDBK-1646 MIL-HDBK-217 MIL-HDBK-454 MIL-HDBK-516 MIL-HDBK-522 MIL-HDBK-525 MIL-HDBK-683 MIL-STD-1353 MIL-STD-1560 MIL-STD-1798 MIL-STD-464 MIL-T-7928 MIL-T-7928/5 MIL-T-81490 MIL-W-22759/87 MIL-W-5088 MIL–STD–5088 Military 5088 modeling moon MS3320 NASA NEMA27500 Nickel nickel plating No Fault Found OEM off gassing Outgassing Over current Overheating of Wire Harness Parallel Arcing part selection Partial Discharge partial discharge at altitude Performance physical hazard assessment Physical Testing polyamide polyimdie Polyimide-PTFE Power over Ethernet power system Power systems predictive maintenance Presentation Preventative Maintenance Program Probability of Failure Product Quality PTFE pull through Radiation Red Plague Corrosion Reduction of Hazardous Substances (RoHS) regulations relays Reliability Research Resistance Revision C Rewiring Project Risk Assessment S&T Meeting SAE SAE Committee Sanitizing Fluids Secondary Harness Protection separation Separation Requirements Series Arcing Service Life Extension Severe Wind and Moisture-Prone (SWAMP) Severity of Failure shelf life Shield Shielding Shrinkage signal signal cable Silver silver plated wire silver-plating skin depth skin effect Small aircraft smoke Solid State Circuit Breaker Space Certified Wires Splice standards Storage stored energy superconductor supportability Sustainment System Voltage Temperature Rating Temperature Variation Test methods Test Pricing Testing testing standard Thermal Circuit Breaker Thermal Endurance Thermal Index Thermal Runaway Thermal Shock Thermal Testing tin Tin plated conductors tin plating tin solder tin whiskering tin whiskers top 5 Transient Troubleshooting TWA800 UAVs UL94 USAF validation verification video Visual Inspection voltage voltage differential Voltage Tolerance volume resistivity vw-1 wet arc white paper whitelisting Winding wire Wire Ampacity Wire Bend Wire Certification Wire Comparison wire damage wire failure wire performance wire properties Wire System wire testing Wire Verification wiring components work unit code

Circuit protection devices are primarily responsible for protection of electrical circuits from low impedance faults. These device types may be thermal, arc fault circuit breaker (AFCB), or integrated within a solid-state power distribution. Regardless of type, their role remains the same.

But circuit protection devices are not error free. In the cases when the circuit protection device opens the circuit without a fault being present, this is called a nuisance trip. The impact of nuisance trips can be difficult to track down and to resolve. In this article, we review common causes for nuisance trips and what the impacts can be to fleet performance.

Impacting Maintenance

First, let’s look at how a nuisance trip is presented to the maintainer. It will typically show on the circuit protection device that there has been a trip. The maintainer will then go and check the devices on the circuit, determine if there is any obvious damage, run a system check, and likely not find a fault. If the fault cannot be found, depending on the device, it may be pulled and replaced to go through the No Fault Found (NFF) cycle. It may not be until several iterations later that the reason for the issue is defined.

Obviously, nuisance trips do not come without consequences. Depending on the device and circuit being protected, the maintenance involved to determine the source can be very high. Because of this, it is important to quickly identify the cause and develop/implement a solution.

arc track resistance
A standard circuit breaker trip curve can be simulated by solid state protection devices. By adjusting the trip levels, potential damage might be reduced, but may also increase the chance of nuisance trip.

Creation of Nuisance Trips

Tracking down the cause of nuisance trips is often not easy. There are several potential causes for these interruptions in which there is not a one-size fits all solution. The following are five potential sources for nuisance trips.

  • Tight control on the circuit protection: In the case, the circuit protection trip conditions can be tuned, nuisance tripping may occur when the protection is set to very stringent conditions. Any increase in current draw might cause circuit protection activation. In these cases, the circuit protection may have been fine-tuned in laboratory conditions and not on the actual aircraft.
  • The load is acting normally, but the electrical signature trips the protection: As part of system integration testing, all conditions should be tested. However, with a variety of operational modes, devices produce different electrical signatures when at elevated temperatures or in a vibrational environment.
  • Errors on other circuits: An example of this is considered as part of AFCB standard AS5692. In this test method, an AFCB is connected to a properly functioning circuit. In a parallel circuit protected by a thermal breaker, arc faults are initiated. The test objective is to ensure that faults that appear do not affect the operation of the AFCB protecting other circuits. However, if a protection device is too sensitive, then there is the possibility that a single fault could have an impact in other areas of the electrical system.
  • The load is acting normally under different power conditions: In this case, the load is doing a good job; however, some variation in the power system appears and is propagated down the system. This voltage variation may trip the circuit protection, or it may cause the load the respond in such a way that is outside normal operation. This is not to say the device has malfunctioned, but the operation is outside of the common operation.
  • Circuit protection malfunction: Some part of the circuit protection device has malfunctioned and can no longer be relied upon to protect the circuit.
  • Each of the preceding potential causes for nuisance trips can be tied to oversensitive trip configurations. The potential response to this is to reduce the sensitivity of these protection devices, but this should not be done without consideration as to why the sensitivity was initially set to a particular level. Perhaps the circuit is connected to the fuel system and must meet the requirements of 25.981 or perhaps the threshold was set to protect the powered device. Whatever the reason, an understanding of what is being protected should be considered before changes are made.

What are Ways to Avoid Nuisance Tripping

The arc fault circuit protection standards, such as AS5692 for AC and AS6019 for DC, specify performance criteria for arc fault circuit protection devices. For integrated power controllers, the same methods can be applied for performance assessment. Showing compliance with these standards does not mean that the protection devices will be fault free, but it does reduce the chances of finding the errors later, such as during system integration or flight testing.

Summary

Nuisance trips can have a negative impact on aircraft performance and can require significant effort to diagnose and resolve. There are, however, methods to reduce the likelihood of this occurring while in flight. Contact Lectromec to find out how we can help evaluate your circuit protection devices.

Michael Traskos

Michael Traskos

President, Lectromec

Michael has been involved in wire degradation and failure assessments for more than a decade. He has worked on dozens of projects assessing the reliability and qualification of EWIS components. In September 2014, Michael was appointed as an FAA DER with a delegated authority covering EWIS certification.