25.1701 25.1703 Accelerated Aging ADMT Aging Systems AIR6808 Aircraft Power System Aircraft Service Life Extension Program (SLEP) arc damage Arc Fault (AF) Arc Fault Circuit Breaker (AFCB) Arc Track Resistance Arcing Arcing Damage AS22759 AS22759/87 AS4373 AS4373 Method 704 AS50881 AS5692 AS6019 AS83519 AS85485 AS85485 Wire Standard ASTM D150 ASTM F2696 ASTM F2799 ATSRAC Attenuation Automated Wire Testing System (AWTS) batteries Bent Pin Analysis Best of Lectromec Best Practice bonding Cable cable testing Carbon Nanotube (CNT) Certification Chafing Chemical Testing Circuit Breaker circuit design Circuit Protection Coaxial cable cold bend comparative analysis Compliance Component Selection Condition Based Maintenance Conductor conductors conduit Connector connectors contacts Corona Corrosion Corrosion Preventing Compound (CPC) Cracking D-sub data analysis data cables degradat Degradation Delamination Derating diagnostic dielectric constant disinfectant Distributed Power System DO-160 dynamic cut through E-CFR Electrical Aircraft Electrical Component Electrical Testing Electromagnetic Interference (EMI) Electromagnetic Vulnerability (EMV) EMC EMF EN3197 EN3475 EN6059 End of Service Life End of Year Energy Storage engines Environmental Environmental Cycling ethernet EWIS Component EWIS Design EWIS Failure EWIS sustainment EWIS Thermal Management EZAP FAA FAA AC 25.27 FAA AC 25.981-1C Failure Database Failure Modes and Effects Analysis (FMEA) FAQs FAR FAR 25.1703 FAR 25.1707 FAR 25.1709 fault tree Fixturing Flammability fleet reliability Flex Testing fluid exposure Forced Hydrolysis fuel system fuel tank ignition functional testing Fundamental Articles Future Tech Green Taxiing Grounding hand sanitizer Harness Design Hazard Analysis health monitoring heat shrink tubing high current high Frequency high speed data cable High Voltage History Hot Stamping Humidity Variation ICAs IEC60172 IEEE Instructions for Continued Airworthiness Insulation insulation resistance IPC-D-620 ISO 17025 Certified Lab Kapton Laser Marking life limited parts Life prediction life projection Lightning maintainability Maintenance Maintenance costs Mandrel measurement Mechanical Testing MECSIP MIL-C-38999 MIL-C-85485 MIL-DTL-17 MIL-DTL-3885G MIL-DTL-38999 MIL-E-25499 MIL-HDBK MIL-HDBK-1646 MIL-HDBK-217 MIL-HDBK-454 MIL-HDBK-516 MIL-HDBK-522 MIL-HDBK-525 MIL-HDBK-683 MIL-STD-1560 MIL-STD-1798 MIL-STD-464 MIL-T-7928 MIL-T-81490 MIL-W-22759/87 MIL-W-5088 Military 5088 modeling MS3320 NASA NEMA27500 No Fault Found off gassing Outgassing Overheating of Wire Harness Parallel Arcing part selection Performance physical hazard assessment Physical Testing polyimdie Polyimide-PTFE Power over Ethernet Power systems predictive maintenance Presentation Probability of Failure Product Quality Radiation Red Plague Corrosion Reduction of Hazardous Substances (RoHS) regulations relays Reliability Research Resistance Rewiring Project Risk Assessment SAE Sanitizing Fluids Secondary Harness Protection Separation Requirements Series Arcing Service Life Extension Severe Wind and Moisture-Prone (SWAMP) Severity of Failure Shield Shielding signal cable silver plated wire smoke Solid State Circuit Breaker Space Certified Wires Splice standards stored energy supportability Sustainment Temperature Rating Temperature Variation Test methods Test Pricing Testing Thermal Circuit Breaker Thermal Endurance Thermal Index Thermal Shock Thermal Testing Tin plated conductors Troubleshooting TWA800 UAVs USAF verification Visual Inspection voltage white paper whitelisting Wire Ampacity Wire Certification Wire Comparison wire damage wire failure wire performance wire properties Wire System wire testing Wire Verification wiring components work unit code

In this article, we will continue the discussion by exploring the NEMA27500 cable. Four sections were covered in the previous article (Specification, identification and shield coverage, conductor size, and wire specification). Editor’s note: Since that article was published, we have also added several tables to help with part identification.

To recall, here is the NEMA27500 cable example that was discussed in part I as we proceed with examining the last three sections of cable.

M27500

H

20

DC

15

T

24

Specification Part Number

Cable Identification and Shield Coverage

Conductor Size

Wire Specification

Number of Wires

Shielding Material

Jacket Material

5 – Number of Wires

This one is fairly self-explanatory. The number here identifies the quantity of individual wires in the cable. The NEMA27500 standard limits this to no more than 15 wires per cable (in our example, the cable specification had 15 wires). While it is possible to have a single basic wire cable, the NEMA27500 specification requires that a single wire have an additional component such as a shield or jacket.

6 – Shielding Materials

A NEMA27500 cable may either by shielded or unshielded. For those that are shielded, there are different means of applying a shield to a cable. The two most common types are tape-wrapped shielding and woven mesh shielding. Shielding that employs a tape-wrap are usually effective at protecting Electromagnetic Interference (EMI) from high-frequencies. The woven mesh shielding is more effective at lower frequencies.

When selecting the shield, what coverage, material type, and construction are really based on the system that is being supported and the circuit EMI susceptibility. It is common to think of signal circuits as being the most commonly shielded cables, but some applications may find a benefit from shielding power wires, particularly near sensitive electrical equipment. Shielding power wires does create a scenario where a ground plane is wrapped around a current carrying wire making it easier to have an electrical short or arcing event in the case of wire damage.

Table source MIL-DTL-27500 Rev H

Symbol for Single Shield Style Symbol for Double Shield Style Shield Material Maximum Temp for Shield Material
U No shield
T V Tin-coated copper, round 150°C (302°F)
S W Silver-coated copper, round 200°C (392°F)
N Y Nickel-coated copper, round 260°C (500°F)
F Z Stainless Steel, round 400°C (752°F)
C R Heavy Nickel coated copper, round 400°C (752°F)
M K Silver-coated high strength copper alloy, round 200°C (392°F)
P L Nickel-coated high strength copper alloy, round 260°C (500°F)
G A Silver-coated copper, flat 200°C (392°F)
H B Silver-coated high strength copper alloy, flat 200°C (392°F)
* # Nickel-coated copper, flat 260°C (500°F)
J D Tin-coated copper, flat 150°C (302°F)
E X Nickel-coated high strength copper alloy, flat 260°C (500°F)
I Q Nickel-chromium alloy, flat 400°C (752°F)

One concern with using shielded materials is the weight. Each additional foot of shielded cable come with a weight penalty that varies based on the shielding needs and the type of metal used. For those that are looking for viable options for weight reduction, metalized fibers or carbon nanotube fibers should be considered (these options would require non-27500 style cables).

7 – Jacket Materials

Representative breakdown of aerospace cable.
If installed into an aerospace platform, the wire and cable choices may impact the aircraft reliability for more than 30 years. Ensure that the correct design choices are made by understanding the cable selection options and performance capabilities.

When selecting cables and evaluating the quality of construction, the quality of the shielding is an excellent place to start; this is among the most difficult parts of cable construction and a quality cable producer can really stand out here. Inherently, the process of weaving the shield conductors is an abrasive process and can cause abrasion between the shield strands and damaged the plating. This damaged plating can expose the substrate and lead to corrosion. For silver plated shielding, the potential for red-plague exists.

Some cable processors have gone to great lengths to improve this shielding process and reduce the frequency of damage shield plating. The expectation should be that there is some damage to the shield plating, but the scale of damage can vary significantly between producers.

The selection of jacket materials should be considered just as important to fluid and mechanical resistance as the single wire primary insulation. This is the surface that will interact most with the installed environment. Because of this, great care should be given to the jacket selection. Many jacket types that are available in the NEMA27500 standard are those that are common to the AS22759 family of wires (e.g. PTFE, XL-ETFE, Polyimide-PTFE). The lessons learned and application considerations for single wires insulated with these materials can also be applied to the cables that employ them for jacket protection too.

Table source MIL-DTL-27500 Rev H

Single Jacket Symbol

Double Jacket Symbol

Jacket Material

Temperature Limit for Jacket Material

00 00 No Jacket
01 51 Extruded white polyvinyl chloride (PVC) 90° C (194°F)
02 52 Extruded clear polyamide in accordance with ASTM D4066 105°C (221°F)
03 53 White polyamide braid impregnated with clear polyamide finisher over a polyester tape 105°C (221°F)
04 54 Polyester braid impregnated with high temperature finishers over polyester tape 150°C (302°F)
05 55 Extruded Clear fluorinated ethylene propylene (FEP) 200°C (392°F)
06 56 Extruded or taped and heat sealed white polytetrafluoroethylene (PTFE) 260°C (500°F)
07 57 White polytetrafluoroethylene (PTFE) treated glass braid impregnated and coated with polytetrafluoroethylene finisher over presintered polytetrafluoroethylene tape 260°C (500°F)
08 58 Cross linked white extruded polyvinylidene fluoride (PVF) 150°C (302°F)
09 59 Extruded white fluorinated ethylene propylene (FEP) 200°C (392°F)
10 60 Extruded clear polyvinylidene fluoride (PVF) 125°C (257°F)
11 61 Tape of natural polyimide combined with clear fluorinated ethylene propylene (FEP) wrapped and heat sealed with (FEP) outer surface 200°C (392°F)
12 62 Tape of natural polyimide combined with fluorinated ethylene propylene (FEP) wrapped and heat sealed with polyimide outer surface 200°C (392°F)
14 64 Extruded white ethylene-tetrafluoroethylene copolymer (ETFE) 150°C (302°F)
15 65 Extruded clear ethylene-tetrafluoroethylene copolymer (ETFE) 150°C (302°F)
16 66 Braid of aromatic polyamide with high temperature finisher over presintered polytetrafluoroethylene (PTFE) tape 200°C (392°F)
17 67 White extruded ethylene chlorotrifluoro-ethylene (ECTFE) 150°C (302°F)
18 68 Clear extruded ethylene chlorotrifluoro-ethylene (ECTFE) 150°C (302°F)
20 70 Extruded white perfluoroalkoxy (PFA) 260°C (500°F)
21 71 Extruded clear perfluoroalkoxy (PFA) 260°C (500°F)
22 72 Tape of polyimide combined with clear fluorinated ethylene propylene (FEP) wrapped and heat sealed with opaque polyimide outer surface 200°C (392°F)
23 73 White, crosslinked, extruded, modified, ethylene-tetrafluoroethylene copolymer (XLETFE) 200°C (392°F)
24 74 Tape layer of white polytetrafluoroethylene (PTFE) wrapped over a tape layer of natural polyimide combined with FEP and heat sealed. 200°C (392°F)

Evaluation of Cables

The use of cables can ease design, installation and provide additional benefits, such as shielding and additional layers of physical protection. The upfront negative of cables is the initial cost, but when selecting cables for applications, the potential time savings associated with implementation should also be considered.

In the next article, we will discuss some of the tests methods that cables must be exposed to as part of the testing and certification process. If you would like a jump start on this, check out Lectromec’s test listing.

Michael Traskos

Michael Traskos

President, Lectromec

Michael has been involved in wire degradation and failure assessments for more than a decade. He has worked on dozens of projects assessing the reliability and qualification of EWIS components. In September 2014, Michael was appointed as an FAA DER with a delegated authority covering EWIS certification.