Cable Overload Resistance

FOR: Wire FOR: Cable $1,170–$1,550

Available wire & cable overload resistance 2 methods for standards including AS22759, BSS7324, EN3475 and samples such as Wire, Cable.

In short circuit conditions, a circuit may run over the designated current for an extended duration before the circuit protection is activated. During this time, a wire/cable may become very hot and potentially exceed its designated thermal rating. Well designed wires/cables will not release any smoke during this fault condition.

The overload resistance test, also known as the smoke resistance test, is designed to examine the durability of the wire insulation under extended periods of internal heating caused by over-current conditions. Additionally, this test is designed to determine if smoke is generated during overload conditions. The duration and current level are wire specification dependent. The test sample is considered to have successfully completed the test if there is no persistent emission of smoke from the sample, the insulation color sustains no significant change, and there is no odor.

Choose the exact method

3 offerings

Pricing and sample requirements vary by test method. Specific test requirements can be added on the request quote page. Final scope and pricing are confirmed by Lectromec usually within 24 hours.

LEC-TST-000112

Smoke Resistance

AS22759 · 5.7.09

Sample type
Wire
Specimens per test
1
Length per test
180 in
$1,550 for one; $820 each additional
LEC-TST-000663

Current Overload

BSS7324 · 7.16

Sample type
Wire
Specimens per test
1
Length per test
180 in
$1,550 for one; $820 each additional
LEC-TST-000775

Overload Resistance

EN3475 · 305

Sample type
Cable
$1,170 for one; $620 each additional

Catalog data generated from Lectromec's controlled Box workbook, version 2655261484000. Internal costing and supplier identities are not published.