Wire & Cable Concentricity Wall Thickness
FOR: Wire FOR: Cable From $200; some methods require a quoteAvailable wire & cable concentricity wall thickness methods for standards including ANSI WC27500 NEMA WC27500, AS22759, AS4373 and others and samples such as Cable, Wire.
Measuring the insulation concentricity and wall thickness is a quality assurance test that can identify uniformity issues. Wires with non-uniform insulation (or cables with non-uniform jackets) will have an unbalanced insulation wall thickness that can make the wire/cable more susceptible to mechanical or electrical failure. This test can be performed on wire gauges ranging from 30AWG to 0000AWG and on wholly tape wrapped and extruded constructions.
Choose the exact method
Pricing and sample requirements vary by test method. Specific test requirements can be added on the request quote page. Final scope and pricing are confirmed by Lectromec usually within 24 hours.
Jacket Wall Thickness
ANSI WC27500 NEMA WC27500 · 4.3.12
- Sample type
- Cable
- Specimens per test
- 1
- Length per test
- 12 in
Concentricity
ANSI WC27500 NEMA WC27500 · 4.3.16
- Sample type
- Cable
- Specimens per test
- 1
- Length per test
- 12 in
Insulation Concentricity and Wall Thickness
AS22759 · 5.5.5
- Sample type
- Wire
- Specimens per test
- 1
- Length per test
- 12 in
Concentricity and Wall Thickness
AS4373 · 101
- Sample type
- Cable
- Specimens per test
- 1
- Length per test
- 6 in
Insulation Thickness
AS81044 · 4.7.5.09
- Sample type
- Wire
- Specimens per test
- 1
- Length per test
- 6 in
Concentricity
AS81044 · 4.7.5.10
- Sample type
- Wire
- Specimens per test
- 1
- Length per test
- 6 in
Concentricity and Wall Thickness
AS85485 · 5.7
- Sample type
- Cable
- Specimens per test
- 1
- Length per test
- 6 in
Concentricity
ASTM D3032 · 15
- Sample type
- Wire
Concentricity
ICEA S-121-733 · 6.9
- Sample type
- Cable
- Specimens per test
- 1
- Length per test
- 12 in
Thickness of Insulation
ICEA S-81-570 · 3.2
- Sample type
- Cable
- Specimens per test
- 1
- Length per test
- 12 in
Neutral Insulation Thickness
ICEA T-27-581 NEMA WC 53-2008 · 3.5.2
- Sample type
- Cable
- Specimens per test
- 1
- Length per test
- 12 in
Thickness of Thermoplastic and Elastomeric Insulation and Sheath
IS 10810 · 6
- Sample type
- Cable
- Specimens per test
- 1
- Length per test
- 60 in
Insulation Thickness
ISO 6722-2011 · 5.2
- Sample type
- Cable
Concentricity
MIL-DTL-25038 · 4.6.2
- Sample type
- Wire
Concentricity
MIL-DTL-25038 · 4.6.2
- Sample type
- Wire
Concentricity of Insulation
MIL-W-81822 · 4.6.13
- Sample type
- Wire
Thickness of Covering
NEMA WC 57 · 6.11
- Sample type
- Cable
- Specimens per test
- 2
- Length per test
- 5 in
Elongation of Jacket
NEMA WC 57 · 6.7
- Sample type
- Cable
- Specimens per test
- 5
- Length per test
- 6 in
Catalog data generated from Lectromec's controlled Box workbook, version
2655261484000. Internal costing and supplier identities
are not published.