Bondability of Insulation to Potting Compounds
Chemical FOR: Insulation $1,350Bonding compounds are often used as a means of protecting electrical terminations from the moisture and other contaminates. Furthermore, proper adhesion of potting compounds can have a positive impact on component durability to vibration and mechanical shocks. The bondability of insulation to potting compounds test evaluates the adhesion to the wire/cable insulation.
In this test, the potting compound is cured on the wire/cable specimen. Once cured, the bondability of the insulation to potting compounds is evaluated by a mechanical pull test.
Parameters that can be changed for this test include:
- Potting compounds
- Sample preparation method
- Curing time
- Curing temperature
Procedure
- Visual examine the specimen and record any defects.
- Mount the specimen into the mold.
- Inject the potting compound into the mold and place into an oven to cure.
- Remove the specimen from the mold.
- Perform a pull test on each of the five specimens.
- Report the maximum pull force, and the potting compound separation/failure mode.
Covered specifications
- ASTM3032 Method 19
- AS4373 Method 102